Maximum loading per tube |
384 pieces/boat(125*125) 336 pieces/boat(156*156) |
|
Process index |
± 3% in tablet, ± 3% between tablets, ± 3% between batches |
|
working temperature |
200~500℃ |
|
Accuracy and length of temperature zone (static closed tube test) |
1200mm±1℃ |
|
Gas flow accuracy |
±1%FS |
|
Air tightness of air circuit system |
1×10-7Pa.m³/S |
|
control |
Fully imported automatic pressure closed-loop regulating system, precise control of reaction vacuum; 40KHz high-frequency power supply; Craft boat soft landing; Full digital control, perfect and safe process control protection. |
|
1 tube, 2 tubes, 3 tubes and 4 tubes are optional; The automatic loading manipulator is optional, and the equipment performance and process performance can be can be comparable with the world's top similar equipment. |