Function and workflow:
Function:Complete the finished capacitor performance inspection
Flow path:Capacitor feeding → ID code reading → Initial testing of capacity and loss → DC withstand voltage inspection → TE insulation test → High cycle current inspection → IR insulation inspection → Capacity loss test → ESR value test → Data uploading to upper computer.
Technical Parameter | ||
NUM |
Project |
Content |
1 |
Product W |
400mm |
2 |
Product L |
250mm |
3 |
Product H |
150mm |
4 |
Production speed |
3PCS/min |
5 |
Work volume |
0.4~0.6Mpa |
6 |
Total driving force |
Approximately 4.0 kW / 380V / 50Hz / 3-phase |
7 |
Equipment external dimensions |
3750×1500×1800mm |
FEATURES | ||
NUM |
Content |
|
1 |
Complete product cycle detection through linear translation |
|
2 |
Customizable functions according to customer requirement |
|
3 |
Space for placing products on fixtures (450X350X170mm) |
|
4 |
Bad data printing |
|