Key Technologies:
Advantages:
Energy-saving battery based on high-frequency power feedback technology
Charging mode: PWM switching power supply mode is adopted to realize constant current and constant voltage charging of the battery.
Advantages: high power conversion efficiency, generally above 85%.


Discharge mode: First, the voltage of the battery is increased by the PWM boost circuit and sent to the inverter power supply, and then gradually increased to be converted into AC power and sent to the AC grid, and finally the battery discharge power is fed back and reused.
Advantages: The discharged electric energy of the power supply is well recycled and reused, and the energy saving effect is obvious.

Equipment structure:
model |
MDSC- S15-96-20 |
MDSC-S14-128-10 |
MDSC-S16-128-10 |
Device channel number |
The whole machine has a total of 96 channels |
The whole machine has a total of 128 channels |
The whole machine has a total of 128 channels |
Dimensions |
1680mm×930mm×1840mm |
1680mm×930mm×1840mm |
1850mm×900mm×1840mm |
Chassis color |
Standard white (customizable) |
||
Fixture form |
Terminal block + alligator clip |
Automatically open the clamp, 80 split rail polymer clamp |
Push down |
Fixture spacing |
150mm |
150mm |
40-155mm |
Support battery specifications |
Polymer battery, prismatic battery |
Polymer battery, soft pack battery |
Square battery, height 110-220mm, thickness 15-75mm, width 65-220mm |
Power supply |
Three-phase five-wire system AC380V±10%, 50HZ |
||
Working power consumption |
≤16KW |
≤11KW |
≤11KW |
working environment |
Temperature 0~40℃, relative humidity≤80% |
||
Cooling method |
Natural intake, upward exhaust |
||
Channel parameters:
model |
MDSC- S15-96-20 |
MDSC-S14-128-10 |
MDSC-S16-128-10 |
Voltage measurement range |
0~5V |
||
Battery voltage range |
Charge 0~4.5V; Discharge 4.5~2V |
||
Constant voltage range |
2.5~4.5V |
||
Voltage accuracy |
±(1‰ reading+1‰ full scale) |
||
Voltage resolution |
1mV |
||
Voltage stability |
≤1‰ |
||
Current range |
Charge 200mA~20A Discharge 200mA~20A |
Charge 100mA~10A discharge 100mA~10A |
Charge 100mA~10A Discharge 100mA~10A |
Current accuracy |
±(1‰ reading+1‰ full scale) |
||
Current resolution |
10mA |
||
Stable current |
≤1‰ |
||
Software functions:
model |
MDSC- S15-96-20 |
MDSC-S14-128-10 |
MDSC-S16-128-10 |
|
动力电池分容设备 |
动力电池分容设备 |
动力电池分容设备 |
way to control |
The software is installed on the computer to connect to the equipment, and the whole cabinet is controlled |
||
communication method |
Serial port, baud rate 57600 |
||
Process settings |
Up to 32 steps and 256 cycles can be set |
||
Charging mode |
Constant current, constant voltage, constant current and constant voltage |
||
Charging cut-off condition |
Voltage, current, time, capacity |
||
Discharge mode |
Constant current |
||
Discharge cut-off condition |
Voltage, time, capacity |
||
Protective function |
Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |
||
time limit |
Arbitrarily set within 0~30000 minutes, the time unit is min |
||
Time accuracy |
≤±1‰ |
||
Sampling inspection cycle |
≤4s |
||
Minimum data recording frequency |
≤5s |
||
Battery sorting |
Sort by (capacity, time, open circuit voltage, discharge platform, etc.) |
||
data processing |
Can record voltage, current, time, capacity and other data, automatically calculate constant current charge ratio, capacity loss, discharge efficiency, average voltage, median voltage and other data, provide data graphs and cycle diagrams; can output generated text, EXCEL, WORD Or MDB database format file |
||